Scan_querystatus, Scan_querystatus_laser, Scannersetfromfile – Argox PA-20 Programming Guide User Manual

Page 28

Advertising
background image

PT-20 Programming Guide

26

Description: This function can send command to set scanner status.

You can see “

Appendix 2

to know about the command setting.

Returns: 0:Send fail.

1:Send OK.

Scan_QueryStatus

Purpose: Query the scanner(CCD) current setting.

Syntax: BOOL SCAN_QueryStatus(int Command1,int Command2,char

*pReturn);

Example call: char ssReturn = 0;

if(SCAN_QueryStatus (6,7, &ssReturn))

_printf_color(COLOR_

RED, “Query OK!”);

Includes: #include

“SDK.h ”

Description: This function can query scanner setting.

You can see “

Appendix 1

to know about the command setting.

Returns: 0:Query fail.

1: Query OK.

Scan_QueryStatus_Laser

Purpose: Query the scanner(Laser) current setting.

Syntax: BOOL SCAN_QueryStatus_Laser (int Command1,int Command2,char

*pReturn);

Example call: char ssReturn = 0;

if(SCAN_QueryStatus_Laser (6,7, &ssReturn))

_printf_color(COLOR_RED, “Query OK!”);

Includes:

#include “SDK.h ”

Description: This function can query scanner setting.

You can see “Appendix 2” to know about the command setting.

Returns: 0:Query fail.

1: Query OK.

ScannerSetFromFile

Purpose: Set scanner setting by scanner setting file. This file is made by utility

“ScanSetting”.

Syntax: BOOL ScannerSetFromFile(char *pssFilePath);

Example call:

If(ScannerSetFromFile (“C:\\data\\scan.axs”))

_printf_color(COLOR_

RED, “Setting OK!”);

Includes:

#include “SDK.h ”

Description:

You can set scanner from “scanner setting file” by this function. This

function can help you set scanner setting easier.

Returns: 0:Load fail.

Advertising