Artel DLC150E User Manual

Digilink, Artel ships the dlc150e configured as follows, Dip switch configurations

Advertising
background image

Simplifying Media Transport

DigiLink

Media

Transport Simplified

QUICK START GUIDE

SW4 CONFIGURATION SIGNAL SOURCE

Function

Off

On

S4

Audio

Source

AES Digital

Analog

S5

Analog

Audio Mode

20 bits

24 bits

Factory Default: All On

Artel ships the DLC150E configured as follows:

Analog audio mode set to 24 bits

Analog audio source with 600 ohm termination

+20 dB peak audio level without clipping

Asynchronous audio embed into destination group #1

Digital video enabled through the BNC connector

SDI grey field enabled if no video is present at the NTSC rate

Alarm enabled if no SFP is present

EMS override enabled (DigiLink Manager can change the DLC150E configuration)

DIP Switch Configurations

SW3 CONFIGURATION PEAK AUDIO

LEVEL

SW

Function

0

+10 dBm

1

+12 dBm

2

+14 dBm

3

+16 dBm

4

+18 dBm

5

+20 dBm

6

+22 dBm

7

+24 dBm

Factory Default: +20 dBm

SW2 CONFIGURATION

ANALOG AUDIO TERMINATION

Function

Off

On

S1

Audio Ch D

High Z

600 ohm

S2

Reserved

-

Must be On

S3

Audio Ch C

High Z

600 ohm

S4

Reserved

-

Must be On

S5

Audio Ch B

High Z

600 ohm

S6

Reserved

-

Must be On

S7

Audio Ch A

High Z

600 ohm

S8

Reserved

-

Must be On

Factory Default: All On

SW2

Controls the termination of the

analog audio inputs

SW3

Controls the peak analog audio

(

Rotary

level that can be handled without

Switch)

clipping

SW4

Controls the signal source selection

for the digital video, type of audio,

and destination group for the

embedding

SW5

Controls multiple module

operating states including:

conditional embedding, non-video

keep-alive signal, line rate for the

standby video pattern, digital audio

rate converter operation, optional

alarm suppresssion for an uninstalled

SFP, and EMS control mode

SW5 CONFIGURATION

MODE CONTROL

Audio Embed Mode

S1

S2

Group Embed

(See SW4: S6, S7)

On

On

Always Embed

On

Off

No Embed

Off

Off

Reserved

Off

On

Factory Default: All On

Function

Off

On

S3

Standby Signal

Artel*

SDI Grey

S4

Standby Type

625 Line

525 Line

S5

Rate Converter

Sync

Async

S6

SFP Alarm

Disabled

Enabled

S7

Reserved

-

Must be On

S8

EMS Override

Local

Control

Remote

Control

•Non-video keep-alive signal.

Factory Default: All On

SW4

SW5

SW2

SW3

Configuration Switch Functions

Function

Off

On

S8

Reserved

-

Must be On

Factory Default: On

SW4 CONFIGURATION SIGNAL SOURCE

S1

S2

S3

Video Source

On

On

On

SDI BNC In

Off

Off

Off

Backplane 1

On

Off

Off

Backplane 2

Off

On

Off

Backplane 3

On

On

Off

Backplane 4

Off

On

On

SFP Opt Receiver

Off

Off

On

Reserved

On

Off

Off

Reserved

Factory Default: All On

S6

S7

AUDIO DESTINATION

On

On

Group 1

Off

On

Group 2

On

Off

Group 3

Off

Off

Group 4

Factory Default: All On

SDI/SDTI 4 Channel Analog/Digital AES Audio

Embed and Optical Transmitter [DLC150E]

Advertising