Artel DLC300 User Manual

Digilink, Artel ships the dlc300 configured as follows, Dip switch configurations

Advertising
background image

Simplifying Media Transport

DigiLink

Media Transport Simplified

QUICK START GUIDE

Artel ships the DLC300 configured as follows:

Transmitter mode selected

All signal types allowed

Electrical input set to BNC

Standby signal set to Artel non-video standby signal

SDI Standby set to 525 line (SD-SDI), 59.94 fps (HD/3G)

Forced bypass is disabled (when forced bypass is enabled, all signal classification,

processing, and reclocking is bypassed)

SDI processing set to No EG34 dithering

ATSC to ASI conversion is disabled

SFP alarms are enabled

Optical reversion is disabled

Video loss alarm is disabled

EMS override is enabled (DigiLink Manager can change the DLC300 configuration)

SW2 CONFIGURATION

S1

S2

S3

Video Source

On

On

On

BNC In

Off

Off

Off

Backplane 1

Off

On

Off

Backplane 2

Off

Off

On

Backplane 3

Off

On

On

Backplane 4

On

Off

Off

Reserved

On

Off

On

Reserved

On

On

Off

Reserved

DIP Switch Configurations

Function

Off

On

S6

Standby

Format

625 Line

(SD-SDI)

525 Line

(SD-SDI)

50fps

(HD/3G)

59.94fps

(HD/3G)

S7

Reserved

-

Must be On

S8

Reserved

-

Must be On

SW3 CONFIGURATION

Function

Off

On

S1

Reserved

-

Must be On

S2

EG34 Dither

Enabled

Disabled

S3

ATSC-ASI

Conversion

Enabled

Disabled

S4

Reserved

-

Must be On

S5

SFP Alarm

Disabled

Enabled

S6

Optical

Reversion

Enabled

Disabled

S7

Alarm On Loss

of Video

Enabled

Disabled

S8

EMS

Override

Local

Control

Remote

Control

Factory Default: All On

SW1

Controls the video rate and forced

bypass function settings

SW2

Controls the input source (BNC IN or

backplane connector) for transmitter

mode and operation of the standby

video pattern generator

SW3

Controls the following functions:

SDI processing, ATSC to ASI video

conversion, SFP alarms, optical

reversion, video loss alarm, and EMS

enable setting

SW1 CONFIGURATION

Function

Off*

On

S1

3G SDI

Disabled

Enabled

S2

HD-SDI

Disabled

Enabled

S3

SD-SDI

Disabled

Enabled

S4

DVB ASI

Disabled

Enabled

S5

ATSC

Disabled

Enabled

S6

Reserved

-

Must be On

S7

Reserved

-

Must be On

S8

All Others

Disabled

Enabled

*All SW1 Switches off for bypass mode

Factory Default: All On

Mode Switch Functions

RX

Receiver Mode

RPT

Repeater Mode (O to O)

TX

Transmitter Mode

SW1

SW2

SW3

Mode

Configuration Switch Functions

Factory Default: All On

Factory Default: All On

S4

S5

Standby Type

On

On

ARTEL*

Off

On

3G 1080p

SDI

Grey

On

Off

SD-SDI

Off

Off

HD 1080i

*Non-video keep-alive signal

3G-SDI Multi-Rate Digital Video Optical Transmitter/

Receiver/Repeater [DLC300]

Advertising