Furthermore, information about the POST status can be obtained by reading the SYS FW
PROGRESS IPMI sensor. Depending on the POST status, this sensor holds the following values.
Table 5-4 Post Results in SYS FW PROGRESS IPMI Sensor Reading Data
Value
Description
0x01
No memory detected
0x02
Memory error. The address and data line test failed.
0x0b
U-boot image CRC mismatch detected
0x0D
Wrong CPU speed.
0xfd
Artesyn specific POST error code. Further information is
provided in the event data byte 3 (see
PROGRESS IPMI Sensor - POST Error Event Codes" on
page 98
)
0x00
One of the remaining POST errors was detected.
Table 5-5 SYS FW PROGRESS IPMI Sensor - POST Error Event Codes
Event Data (Byte 3)
Description
0x1E
Error accessing the switch devices
0x03
Error in network loop back test
0x20
Error in network PHY test
0x1F
Error in glue logic (FPGA) test
0x0A
Error in I2C bus test
0x16
Error in RTC test
0x09
Error in flash test
0x21
Error in CPU test
0x22
Error in PCI bus test