C.4 editing vme settings, Vme configuration parameters – Artesyn MOTLoad Firmware Package User's Manual (February 2015) User Manual
Page 264

VME Configuration Parameters
MOTLoad Firmware Package User’s Manual (6806800C24D)
264
vmeCfg –s –r188
Displays Special PCI Target Image Register state
vmeCfg –s –r400
Displays Master Control Register state
vmeCfg –s –r404
Displays Miscellaneous Control Register state
vmeCfg –s –r40C
Displays User AM Codes Register state
vmeCfg –s –rF70
Displays VMEbus Register Access Image Control Register state
C.4
Editing VME Settings
To edit a changeable VME setting, for example on a Universe II PCI-to-VMEbus bridge, type the
following at the firmware prompt:
vmeCfg –e –m
Edits Master Enable state
vmeCfg –e –i(0 - 7)
Edits selected Inbound Window state
vmeCfg –e –o(0 - 7)
Edits selected Outbound Window state
vmeCfg –e –r184
Edits PCI Miscellaneous Register state
vmeCfg –e –r188
Edits Special PCI Target Image Register state
vmeCfg –e –r400
Edits Master Control Register state
vmeCfg –e –r404
Edits Miscellaneous Control Register state
vmeCfg –e –r40C
Edits User AM Codes Register state