Installation (for qualified installers only), Electrical connection – Avalon Firestyles 21 DV RV User Manual

Page 13

Advertising
background image

Installation (for qualified installers only)

13

© Travis Industries

4060517

100-01158

Optional Gas Line Location

Secure the cover plate to the access cover with the

nuts removed in step “b”. Secure the access cover to

the fireplace with the screws removed in step “a”.

d

1/4" Nutdriver

Remove the access cover on the

side of the fireplace.

a

HINT: remove the

control cover for

easier access.

5/16" Wrench

Remove the cover plate on the bottom

of the fireplace (save these nuts).

b

c

Position the gas inlet assembly over the hole in the

baseplate and secure using the screws removed in

step “a” (NOTE: bend the flex tube as shown below -

this will ease in positioning of the gas inlet assembly).

Electrical Connection

Make sure the household breaker is shut off prior to working on any electrical lines.

The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)

The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

Electrical Line Location

Optional Location
The optional electrical inlet is flush
with the base of the fireplace.

NOTE: a 3-1/2" diameter hole is required to
provide clearance for the electrical inlet screws.

10-1/2"

8"

Standard Location

10-1/2"

Front of Fireplace