Features and specifications, Features, Installation options – Avalon Firestyles 21 DV RV User Manual

Page 6: Heating specifications, Dimensions

Advertising
background image

6

Features and Specifications

© Travis Industries

4060517

100-01158

Features

•

Works During Power Outages (millivolt system)

•

High Efficiency

•

Optional Thermostat or Remote Control

•

Realistic "Wood Fire" Look

•

Quiet Blower for Effective Heat Distribution

•

Convenient Operating Controls

•

Variable-Rate Heat Output

•

Low Maintenance

Installation Options

•

Residential or Mobile Home

•

Straight or Corner Placement

•

Flush or Recessed Face

•

Raised or Floor Placement

•

Internal or External Chase

•

Horizontal or Vertical Vent

•

Bedroom Approved

Heating Specifications

Natural Gas

Propane

Approximate Heating Capacity (in square feet)*

Up to 650Up to 650

Maximum BTU Input Per Hour

16,500

16,500

Minimum BTU Output on Low

10,500

9,380

Steady State Efficiency** (with blowers on)

Up to 77.2%

Up to 74.5%

AFUE (Annual Fuel Utilization Efficiency)

63%

63%

*

Heating capacity will vary with floor plan, insulation, and outside temperature.

**

Efficiency rating is a product thermal efficiency rating determined under continuous
operation independent of installed system.

Dimensions

34-1/8”

12-5/8

” (Includes

Stand-Offs)

4-7/8”

20-1/8”

See “Gas Line

Requirements” for details

on the gas inlet.

The lifting handles

may be rotated down.

27-1/4”

1-3/4”

Advertising