Caution, Safety label, Listing label – Avalon Firestyles 21 DV RV User Manual
Page 47: Travis industries

Safety Label
47
© Travis Industries
4060517
100-01158
Listing Label
The safety (listing) label is attached to the operating tag (chained to the fireplace near the gas
control valve). A copy is shown below
21DV RV
Vented Gas Fireplace Heater
Tested to:
ANSI Z21.88-2002 “V
ented Gas Fireplace Heater” and UL
307b-1995 “Gas Burning Heating
Appliances for Manufactured Homes”.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.1/NFP
A
5
4
.
Installation
in
Manufactured
or
Mobile
Homes
must
conform
with
Manufactured
Home
Construction
and
Safety
Standard,
T
itle
24
CFR
,
Part 3280.
This vented
gas
fireplace
heater
is
equipped
at
the
factory
for
use
with natural
gas. If
conversion
to
propane
(LP) is
desired,
the
optional
factory conversion kit must be used.
This
appliance
is
only
for
use
with
the
type
of
gas
indicated
on
the
rating
plate
and
may
be
installed
in
an
aftermarket,
permanently
located,
manufactured
(mobile)
home where
not
prohibited
by
local
codes.
See
owner
’s
manual
for
details.
This appliance
is
not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance
must be
properly
connected
to
a
venting
system
in
accordance
with the
manufacturer
’s
i
nstallation
instructions.
Use
only
approved coaxial direct vent system to vent this appliance to the exterior
. See owner
’s
manual for approved brands of venting.
W
ARNING:
Improper
installation,
adjustment,
alteration,
service
or
maintenance
can
cause
injury
or
property
damage.
Refer
to
th
e
owner
’s
information
manual
provided
with
this
appliance.
For
assistance
or
additional
information
consult a
qualified
installer
,
servic
e agency
or
the gas supplier
.
VENTED GAS FIREPLACE HEA
TER – NOT FOR USE WITH SOLID FUEL
CAUTION:
Hot
while
in
operation.
Do
not
touch.
Severe
burns
may
result.
Keep
children,
clothing,
furniture,
gasoline
and
other
liquids
having
flammable
vapors
away
.
Do
not
operate
this
appliance
with
glass
removed,
cracked
or
broken.
Replacement
of
the
panel(s) should be done by a licensed or qualified service person.
4800 Harbour Pointe Blvd. SW Mukilteo, W
A
98275
Minimum Clearances to Combustibles
Faceplate to
Adjacent W
a
ll
. . . . . . . . . . . .
1
”T
op to enclosure (from stand-offs)
. . . . . . . . . . . . . . . . . . . .
0
”
W
ood Floor Beneath Fireplace
. . . . . . . . .
0
”Sides to enclosure
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.5”
Back to enclosure
. . . . . . . . . . . . . . . . . . .
0
”
Faceplate to 8” Mantel (no eyebrow)
. . . . . . . . . . . . . . . . . .
7
”
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)
............
16
,500
16,500
M
inimum Inlet Pressure (inches W
.C.)
...............
11
”5
.5
”
Input Rate on “LO” (BTU/Hr)
...........
12,800
13,800
M
aximum Inlet Pressure (inches W
.C
.)
..............
13
”7
”
Manifold Pressure on “HI” (inches W
.C
.)
..........
10
”3
.5
”
For natural gas when equipped with the following drill size orifice: DMS 49
For propane when equipped with the following drill size orifice: DMS 56
This appliance is equipped
fo
r use only at altitudes 0-2,000 feet.
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner
’s
m
anual for information on making these changes.
Electrical Rating:
11
5v
, 1.5
A
m
ps, 60 Hz
Manufacture
20
04
Jan.
A
p
r.
Jul.
Oct.
Date:
20
05
Feb.
M
ay
Aug.
N
ov
.
20
06
M
ar
.
Jun.
Sep.
Dec.
IGN 540
Report No. 028-S-56-5
Certified for USA