IMPORTANT: The glass must be allowed to
warm slowly and evenly. Such materials as
pitch/wax laden logs, very dry mill end lumber
and large amounts of paper or cardboard
boxes can create an excessively hot fire and
should not be burned in this fireplace. Always
keep the fire well back from the doors and
never allow flames to contact the glass.

WARNING: Fireplaces

equipped with glass doors

should be operated only with

doors fully opened or doors fully

closed. Doors, if left partly open,

may draw gas and flame out of

the fireplace opening creating

risks of both fire and smoke.

Cleaning Glass
Clean glass with any commercial glass
cleaner or soap and water. Do not use any
abrasive material to clean glass. Do not clean
glass with any cool water if glass is still hot
from the fire and smoke.
A gas line or gas log lighter may be installed
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an
automatic shutoff device and complying with
the Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces, ANSI Z21.60

or American Gas Association draft requirements
for Gas Fired Log Lighters for Wood Burning
Fireplaces, Draft NO. 4
dated August, 1993.
If you wish to install an unvented (vent-free)
gas log set, only unvented gas log sets which
have been found to comply with the standard
for unvented room heaters, ANSI Z21.11.2 are
to be installed in this fireplace.

DAMPER HANDLE OPERATION

The damper handle opens and closes the
damper blade and is located in the upper rear
side of fireplace just above rear bricks. Rotate
handle counterclockwise slightly to disengage
from retaining bracket. Swing slowly toward
opening of fireplace. Engage handle to sec-
ondary bracket located at front of fireplace
inner wall (see Figure 27).

opeRation and Maintenance

Continued

CAUTION: When operating

damper door, please be aware of

sharp edges and corners. Open

and close damper door slowly to

avoid injury.

WARNING: Risk of fire! Re-

place grate with DESA Heating,

LLC model 109496-01 grate only.

This grate has been designed to

keep the operation of your fire-

place safe and efficient.

Figure 27 - Operating Damper Handle

Damper
Handle

Retaining
Bracket
(Holds
Damper
Door
Closed)

Swing Door Down to Open

Swing Door
Up to Close

Secondary
Retaining
Bracket
(Holds
Damper
Door
Open)

FULLY OPEN POSITION

FULLY CLOSED POSITION