Installation, Selecting fireplace location, Minimum clearance to combustibles – Desa F48H(i)(R) User Manual

Page 4: Framing

Advertising
background image

www.desatech.com

122272-01C

4

installation

SELECTING FIREPLACE LOCATION

To determine the safest and most efficient
location for the fireplace, you must take into
consideration the following guidelines:
1. The location must allow for proper clear-

ances (see Figures 1 and 2).

2. Consider a location where the fireplace

will not be affected by drafts, air condition-
ing ducts, windows or doors.

3. A location that avoids the cutting of

joists or roof rafters will make installation
easier.

4. An outside air kit is available with this

fireplace (see Optional Outside Air Kit on
page 5).

MINIMUM CLEARANCE TO
COMBUSTIBLES

Back and sides of fireplace

1

1

/

2

" min.*

Front of fireplace

48" min.

Floor**

0" min.

Perpendicular wall to opening 18" min.
Top spacers

0" min.

Mantel clearance

see Mantels,

page 5

Chimney outer pipe surface

2" min.

* Not required at nailing flanges
** See step 2 of Framing

WARNING: Do not pack re-

quired air spaces with insulation

or other materials.

Minimum/Maximum Chimney Height
The minimum height of the chimney, mea-
sured from the base of the fireplace to the
flue gas outlet of the termination, is 16 feet for
straight flue or a flue with one elbow set. The
maximum distance between elbows is 6 feet.
For systems with two elbow sets, the minimum
height is 22 feet. The maximum height of any
system is 50 feet. This measurement includes
the fireplace, chimney sections and the height
of the termination assembly at the level of the
flue gas outlet (see Figure 15, page 9).

FRAMING

1. Frame the opening for the fireplace using

the dimensions shown in Figures 1 and 2.

2. If the fireplace is to be installed directly

on carpeting, tile (other than ceramic) or
any combustible material including wood
flooring, the fireplace must be installed

60.875"

65.7"

71.5"

76.375"*

31.625"

Secure Fireplace
To Hearth Spacer
Using Straps Provided
(Sides and Rear)

* With Hearth Spacer

Figure 1 - Framing Dimensions

Figure 2 - Corner Installation

107.3"

78.875

"

Maintain 1

1

/

2

"

Clearance at Sides and

Back of Fireplace

1

1

/

2

" Clearance

Not Required at
Nailing Flanges

on a hearth spacer designed for use with
this fireplace (see Replacement and Ac-
cessory Parts
, page 18).

3. Set the fireplace directly in front of this

opening and slide the unit back until the
nailing flanges touch the side framing.

4. Check the level of the fireplace and shim

with sheet metal if necessary.

5. Before securing fireplace to prepared fram-

ing, the ember protector (provided) must be
placed between the hearth extension (not
supplied) and under the bottom front edge
of the fireplace to protect against glowing
embers falling through. If the fireplace is
to be installed on a raised platform, a Z-
type ember protector (not supplied) must
be fabricated to fit your required platform
height. The ember protector should extend
under the fireplace a minimum of 1

1

/

2

". The

ember protector should be made of galva-
nized sheet metal (28 gauge minimum to
prevent corrosion.

6. Using screws or nails, secure the fireplace

to the framing through flanges located on
the sides of the fireplace.

Advertising
This manual is related to the following products: