VenTing inSTALLATion

Continued

ChASE INSTALLATIONS

Instructions for chase installations are

included with the chase style termination

chosen. In a multiple chase installation, be

sure to provide adequate distance between

terminations to prevent smoke spillage from

one termination to another. Terminations must

be separated a minimum of 30" center to cen-

ter and stacked at a minimum vertical height

difference of 18" (see Figure 26).
Note: If a decorative shroud is to be installed,

contact the manufacturer for specifications.

FINISHING FIREBOx

Installing Firebox Facing

Any noncombustible material may be used

for facing (glass, tile, brick, etc.) as long as

proper clearances are adhered to and firebox

openings are not obstructed in any way (see

Figure 27).
Use only heat resistant, noncombustible mor-

tar or adhesive when securing facing material

to front of firebox. When placing facing at

upper edge of effective opening of firebox,

provide “L” shaped piece of metal extending

full width of opening (see Figure 27).
Secure with sheet metal screws at a distance

high enough from edge so it doesn't interfere

with operation of doors. This assures that fac-

ing material will not block openings.

30" Min.

30" Min.

18"

Min.

Typ.

Figure 26 - Multiple Chase Installation

1"

Space

Screen

Chase

Top

1" Non-

com-

bustible

Spacer

“L” Shaped

Metal

Support

Noncombustible

Facing Material

Noncombustible

Facing Material

Do Not

Block

Opening

Figure 27 - Fireplace Facing (Your

Fireplace May Vary from Illustration)