Figure 28 - Gas Line Knockout

Side

Firebrick

Finished

Side

Refractory

Knockout

Plug

Outside of

Fireplace

Gas Line

Conduit
Insulation

Gas

Conduit

Cover

1/2" Dowel

Remove

Knockout

WARNING: A qualified ser-

vice person must connect gas

supply. Follow all local codes.

NOTICE: Before you proceed, make sure your

gas supply is turned off.

A gas line may be installed for the purpose

of installing a vented or vent-free decorative

gas appliance available through your local

distributor. Use only 1/2" black iron pipe and

appropriate fittings. When installing a gas

line, a shutoff valve designed for installation

outside the appliance is recommended.
1. Remove knockout indentation on refrac-

tory or firebrick wall located approximately

2" above the refractory hearth floor. The

knockout indentation must be firmly

tapped with any solid object such as a

1/2" dowel until it is released. Remove

fragmented portions of refractory (see

Figure 28).

2. Remove gas line cover plate located on

rear of fireplace and pull out insulation

from gas line conduit sleeve. Save insula-

tion for reuse.

3. Run 1/2" black iron gas line into the firebox

through the rear at 11

1

/

4

" from floor and

through gas line conduit sleeve (if using

a raised platform, add height). Provide

sufficient gas line into firebox chamber

for fitting connection (see Figure 29).

Note: Secure incoming gas line to wood

framing to provide rigidity for threaded end.

4. Repack insulation around gas line and into

sleeve opening. Seal any gaps between

gas line and refractory knockout hole with

refractory cement or commercial furnace

cement, Install the gas appliance or cap

off gas line if desired.

Seal

Opening

with

Refractory

Cement

Outside of

Fireplace

Gas

Line

Conduit

Repack

Insulation

Incoming

1/2" Black

Iron Pipe

Side

Firebrick

Finished

Side

Provide Enough Threaded

End for Fitting Connection

Figure 29 - Gas Line Installation

oPTionAL gAS Line inSTALLATion

CAUTION: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is on, apply

soap and water solution to all

connections and joints. Bubbles

forming show a leak. Correct

all leaks at once. DO NOT USE

AN OPEN FLAME FOR LEAK

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK

IS DETECTED. LEAK TESTING

ShOULD BE DONE BY A QUALI-

FIED SERVICE PERSON.

The gas pipe is intended for connection to

an unvented gas log set or a decorative gas

appliance.
If using an unvented gas log set, ONLY

UNVENTED GAS LOG SETS WHICH HAVE

BEEN FOUND TO COMPLY WITH THE

STANDARDS FOR UNVENTED ROOM

HEATERS, ANS/IAS/AGA Z21.11.2, ARE TO

BE INSTALLED IN THIS FIREBOX.
If installing a decorative gas appliance, the

decorative gas appliance must comply with

the Standard for Decorative Gas Appliances

for Installation in Solid Fuel Burning Fire-

places, ANS Z21.60-1996 and shall also be

installed in accordance with the National Fuel

Gas code, ANS Z223.1-1996.