Venting installation – Desa (V)368ST User Manual

Page 7

Advertising
background image

www.desatech.com

55511E

7

Figure 13 - Pipe Connection

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

368STM

See-Through

66

1

/

4

"

V368ST

See-Through

54"

(V)12-8DM

Flue Pipe

10

5

/

8

"

(V)18-8DM

Flue Pipe

16

5

/

8

"

(V)24-8DM

Flue Pipe

23

5

/

8

"

(V)36-8DM

Flue Pipe

34

5

/

8

"

(V)48-8DM

Flue Pipe

46

5

/

8

"

VRTL-8DM

VRTTL-8DM

Round Top

Termination

6"

VETL-8M

VETO-8DM

VETLO-8DM

Econo-Top

Termination

1" to 12"

Hemmed

End

8" Stainless

Inner Pipe

Lanced Side

Up

12

3

/

8

" Galvanized

Outer Pipe

Figure 12 - Outside Air Kit Installation

Secure to Collars with

Duct Tape or Screws

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Termination

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

ChIMNEY PIPE

The DESA Heating, LLC chimney system is

a snap-lock, double-wall pipe. It consists of a

stainless steel inner flue pipe(s), a galvanized

outer pipe and a wire spacer. Each section of

pipe comes in lengths of 12", 18", 36" and 48".

The actual lineal gain for each is measured

after each section is fully connected. Lineal

gain is the actual measurable length of a part

after two or more parts are connected.

PIPE INSTALLATION

The pipe sections must be assembled indepen-

dently as the chimney is installed. When connect-

ing chimney directly to the firebox, the inner flue

VenTing inSTALLATion

Continued

where the chimney penetrates a floor or ceil-

ing joist space. Their purpose is to establish

and maintain the required clearance between

the chimney and the combustible materials.
When penetrating a floor or ceiling at an angle,

use firestop spacer number V30FS-8DM (see

Replacement and Accessory Parts, page 14).
When the pipe passes through a framed open-

ing into a living space above, the firestop must

be placed onto the ceiling from below as shown

in Figure 14, page 8. When the pipe passes

through a framed opening into an attic space

above, the firestop must be placed on the attic

floor as shown in Figure 15, page 8.

SUPPORT SECTIONS

The chimney support section is a 4" strap

pipe section must be installed first with the lanced

side up. The outer pipe section can then be in-

stalled over the flue pipe section with the hemmed

end up. Press down on each pipe section until the

lances securely engage the hem on the firebox

starter. The wire will assure the proper spacing

between the inner and outer pipe sections.

Continue to assemble chimney sections as

outlined above, making sure that both the inner

and outer pipe sections are locked together

(see Figure 13). When installing double wall

snap-lock chimney together, it is important to

assure the joint between the chimney sections

is locked. Check by pulling chimney upward

after locking. The chimney will not come apart

if properly locked. It is not necessary to add

screws to keep the chimney together.

FIRESTOP SPACERS VFS-8DM

(24 PACK)

Firestop spacers are required at each point

WARNING: The opening in the

collar around the chimney at the top

of the firebox must not be obstruct-

ed. Never use blown insulation to

fill the chimney enclosure.