BECKHOFF BK7500 User Manual

Page 15

Advertising
background image

Basic information

BK7500

15

Function type of the channel

Assignment level

1.

Analog outputs

byte-wise assignment

2.

Digital outputs

bit-wise assignment

3.

Analog inputs

byte-wise assignment

4

Digital inputs

bit-wise assignment


Analog inputs/ouputs are representative of other complex multi-byte signal
bus terminals (RS232, SSI sensor interface, ...)

Overview of the subdivision of the process image in the bus coupler:


Output data in the bus
coupler

O0
...

byte-oriented data

...
Ox

Ox+1

bit-oriented data

Ox+y


Input data in the bus
coupler

I0
...

byte-oriented data

...
Ix

Ix+1
...

bit-oriented data

...
Ix+y



The path from the I/Os to
the PROFIBUS process
image

Sercos

Sercos

Mapping list

Mapping by

byte

Mapping

list

Mapping by bit

and byte

Buildt inside the master by
software on the PC

Buildt automatically
by the bus coupler

E

E

E

E

A

A

A

A

CPU

Bk7500