Ii installation / commissioning, Ii.1 important notes, Installation / commissioning – BECKHOFF AM2000 User Manual

Page 15: Ii.1, Important notes

Advertising
background image

II

Installation / Commissioning

II.1

Important notes

l

Check that the servoamplifier and motor match each other. Compare the rated volt-

age and rated current of the unit. Carry out the wiring according to the wiring

diagram in the Installation and Commissioning Instructions for the servoamplifier.
The connections to the motor are shown on page 23 Notes on the connection

methods can be found on page 18.

l

Ensure that there is proper earthing of the servoamplifier and the motor.

l

Route the power and control cables as separately as possible from one another

(separation > 20 cm). This will improve the immunity of the system to electromag-

netic interference.
If a motor power cable is used which includes integral brake control leads, then

these brake control leads must be shielded. The shielding must be connected at

both ends (see under Installation Instructions for the servoamplifier).

l

Install all cables carrying a heavy current with an adequate cross-section, as per

EN 60204. The recommended cross-section can be found in the Technical data.

Caution!
If a servoamplifier of the series AX2000 is used and the motor cable exceeds
25m, a boxed choke (type 3YL-20, manufactured by BECKHOFF) and motor
leads with the following diameters must be used:

Servoamplifier

choke box

Max. cable diameter

AX2001...06

3YL-20

4 x 1mm²

AX2010

3YL-20

4 x 1,5mm²

AX2020

3YL-20

4 x 2,5 mm²

l

Connect up all shielding via a wide surface-area contact (low impedance) and
metallized connector housings or EMC-PG glands.

l

Check the compliance to the permitted radial and axial forces F

R

and F

A

.

When you use a toothed belt drive, the minimal permitted diameter of the pinion
e.g. follows from the equation: d

M

F

R

min

³

´

0

2 .

l

Ensure that there is adequate heat transfer in the surroundings and the motor

flange, so that the maximum permissible flange temperature is not exceeded in S1
operation.

Caution!
Never undo the electrical connections to the motor while it is energised. A

dangerous voltage, resulting from residual charge, can be still present on the
capacitors up to 300 seconds after switch-off of the mains supply.
Measure the DC-link voltage and wait until it has fallen below 40V.
Even when the motor is not rotating, control and power leads may be live.

Motor series AM227..297

15

BECKHOFF

12/2001

Installation / Commissioning

Advertising