IV.1

Delivery package, transport, storage, maintenance, disposal

Delivery package:— Motor from the AM227..297 series

— Technical description (documentation), 1 copy per delivery
— Motor package leaflet (short info)

Transport:

— Climate category 2K3 to EN 50178

Transport temperature—25...+70°C, max. 20K/hr change

Transport humidity rel. humidity 5% - 95% , no condensation

— only by qualified personnel

— only in the manufacturer’s original recyclable packaging

— avoid shocks

— if the packaging is damaged, check the motor for visible damage.

Inform the carrier and, if appropriate, the manufacturer.

Packaging:

Motor type

Carton

Pallet or skeleton box

Max.stacking height

AM227/37

X

10

AM247

X

6

AM257

X

6

AM277

X

5

AM297

X

1

Storage:

— Climate category 1K4 to EN 50178

Storage temperature

—25...+55°C, max. variation 20K/hr.

Humidity

rel. humidity 5% - 95%, no condensation

— only in the manufacturer’s original recyclable packaging
— max. stacking height

see table under Packaging

— Storage time

unlimited

Maintenance:

— Only by qualified personnel
— The ball bearings have a grease packing which is adequate for

20,000 hours of operation under normal conditions. The bearings

should be replaced after 20,000 hours of operation under rated

conditions.

— Check the motor for bearing noise every 2500 operating hours,

respectively each year. If any noises are heard, then the operation

of the motor must stop, the bearings must be replaced.

— Opening the motor invalidates the warranty.

Cleaning:

— If the housing is dirty:

clean with Isopropanol or similar.

do not immerse or spray

Disposal:

— The disposal should be carried out by a certified disposal company.

Ask us for addresses.