II.2.1

Connection methods

l

Carry out the wiring in accordance with the valid standards and regulations.

l

Only use our preassembled shielded leads for the resolver and power connections.

l

Connect up the shielding according to the wiring diagrams in the Installation

Instructions for the servoamplifier.

l

Incorrectly installed shielding inevitably leads to EMC interference.

In the table below you find all leads supplied by us. Further information referring to chemi-

cal, mechanical and electrical qualities can be received from our applications department.
Insulating material
Sheathing

- PUR (Polyurethane, identification 11Y)

core insulation - PETP (Polyesteraphtalate, identification 12Y)
Capacity
Motor lead

- less than 150 pF/m

Resolver lead - less than 120 pF/m
Technical Data

All leads are suitable for trailing.

Technical data refer to mobile usage of leads.
Life time : 1 Million bending cycles

The temperature range refers to the operation temperature.

Identification:

N

= numbered cores

F

= cores with colour code according to DIN 47100

B

= cores with letter identification

( )

= shielding

Cores
[mm²]

Identification Temperature range

[°C]

Cable diameter

[mm]

Bending radius

[mm]

Remarks

(4x1,0)

F

-30 / +80

10,5

105

Motor lead

(4x1,5)

B

-30 / +80

11,3

115

(4x2,5)

N

-5 / +70

12,7

125

(4x1,0+(2x0,75))

F

-30 / +80

12

120

Motor lead with

integral brake

control leads

(4x1,5+(2x0,75))

B

-10 / +80

12,5

125

(4x2,5+(2x1))

B

-30 / +80

13,8

140

(4x2x0,25)

F

-30 / +80

6,9

60

Resolver lead

18

Motor series AM227..297

Installation / Commissioning

12/2001

BECKHOFF