your feet flat on the ground. Make sure to rest your arm and

move it. Always make sure that the cuff is at heart level.

Otherwise significant deviations can occur. Relax your arm

and the palm of your hand.

• In order not to distort the result, it is important to keep still

during the measurement and not talk.

Select memory
Switch on the blood pressure monitor with the button. Select

the required memory space by pressing the function key +. You

have two memories (60 memory spaces each) in order to save

the test results of 2 different people separately, or else save

measurements in the morning and evening separately.
Measuring blood pressure
• Put on the cuff as described previously and assume the posi-

tion in which you want to carry out the measurement.

• Using the buttons +, select the user memory 1 or 2. Start the

measurement process by pressing button . After check-

ing the display with all digits lighting up, the monitor will

automatically inflate. Following the self-test, during which all

display elements briefly appear, the measurement begins.

During inflation the device already determines measured val-

ues used to estimate the required inflation pressure. If this

pressure is insufficient, the device automatically inflates by

another.

• Then the pressure in the cuff is slowly released and the pulse

is measured.

• When the measurement has been completed, the remain ing

air pressure is released very quickly. The pulse, the systolic

and the diastolic blood pressure are displayed.

• You can interrupt measurement at any time by pressing the

button .

• The icon appears if it has not been possible to perform

the measurement properly. Observe the section in these

instructions on error messages/troubleshooting and repeat

the measurement.

• The device switches off automatically after 1 minute.
Wait at least 5 minutes before taking another measurement!
Evaluating results
Cardiac arrhythmia:
This instrument can identify possible cardiac arrhythmia disor-

ders during measurement and if necessary indicates the meas-

urement with the flashing icon

.

This may be an indicator for arrhythmia. Arrhythmia is a condi-

tion where the heart rhythm is abnormal as a result of defects

in the bioelectrical system controlling the heart beat. The

symptoms (omitted or premature heart beats, slow or exces-

sively fast heart rate) may be caused, among other things,

by heart disease, age, physical predisposition, excessive use

of stimulants, stress or lack of sleep. Arrhythmia can only be

ascertained through examination by your doctor.

Repeat the measurement if the flashing icon

is displayed

after the measurement. Please note that you should rest for 5

minutes between measurements and not talk or move during

the measurement. If the icon

appears often, please

contact your doctor. Any self-diagnosis and treatment based

on the test results may be dangerous. It is vital to follow your

doctor’s instructions.