Figure 6 - Minimum Mantel Clearances

Without Using Hood

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of
Fireplace
Opening

Underside
of Mantel
Shelf

12"

8"

(A)

18"

14"

20"

17"

22"

19"

24"

20"

All minimum
distances are
in inches

Log Set
24" Models

18" Model

2

1/2

"

6"

8"

10"

Mantel Shelf

INSTALLATION

Continued

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

Heat Resistant
Material

(A)

Noncombus-
tible Material
Distance (A)

Requirements for Safe
Installation

12" or more

Noncombustible material OK.

Between 8"
and 12"

24" Model: Install fireplace
hood accessory (GA6050,
GA6052 or GA605, see
Accessories, page 25). 18"
Model: Noncombustible ma-
terial OK

Less than 8"

Noncombustible material
must be extended to at least
8". See Between 8" and 12",
above. If you cannot extend
material, you must oper-
ate heater with flue damper
open.

Figure 7 - Minimum Mantel Clearances

When Using Hood

Minimum Non-
Combustible
Material

8"
Min.

12" 15" 18"

All minimum
distances are
in inches

Log Set
18" and 24"

Models

20"

2 1/2"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050,
GA6052 or
GA6053)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note:

If using a mantel, proceed to If Using

Mantel. If not using a mantel, follow the informa-

tion below.

You must have noncombustible material(s) above

fireplace opening. Noncombustible materials (such

as slate, marble, tile, etc.) must be at least 1/2"

thick. With sheet metal, you must have noncom-

bustible material behind it. Noncombustible mate-

rial must extend at least 8" up (for all models). If

noncombustible material is less than 12", you must

install the fireplace hood accessory (24" models

only). See Figure 5 for minimum clearances.

If Using Mantel
You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2" thick. With sheet metal, you must have non-

combustible material behind it. Noncombustible

material must extend at least 8"up (for all models).

If noncombustible material is less than 12", you

must install the fireplace hood accessory. Even if

noncombustible material is more than 12", you

may need the hood accessory to deflect heat away

from your mantel shelf (24" models only). See

Figures 5, 6 and 7 for minimum clearances.
IMPORTANT

: If you cannot meet these minimum

clearances, you must operate heater with chimney

flue damper open. Go to Installing Dmanper

Clamp Accessory for Vented Operation, page 11.