Troubleshooting – Desa VF-24N-BTB User Manual

Page 22

Advertising
background image

www.desatech.com

111826-01G

22

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Orange flame in burner during

burner combustion

Slight smoke or odor during initial

operation

Heater produces a whistling noise

when burner is lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Moisture/condensation noticed

on windows

Remote does not function

Heater produces a clicking/tick-

ing noise just after burners are lit

or shut off

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective

1. Residues from manufacturing

processes and logs curing

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Not enough combustion/venti-

lation air

1. Battery is not installed. Battery

power is low

1. Metal expanding while heating

or contracting while cooling

REMEDY

1. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 19)

2. Replace gas regulator

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum instal-

lation clearances (see pages 9

through 11)

4. Clean burner (see Cleaning

and Maintenance, page 19)

or replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet

cleaners, or similar products

1. Refer to Air for Combustion

and Ventilation requirements

(page 6)

1. Replace batteries in receiver

and hand-held remote control

1. This is common with most

heaters. If noise is excessive,

contact qualified service

person

Advertising
This manual is related to the following products: