CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing heater

in rooms without enough ventilation air may cause

mildew to form from too much moisture. See Air

for Combustion and Ventilation, page 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP)

for your unit. If your gas supply is not correct, do

not install heater. Call dealer where you bought

heater for proper type heater.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining wall.

Minimum Fireplace Clearance to
Combustible Materials

Side Wall - 16", Ceiling - 42", Floor - 5"

INSTALLATION

Continued

Carefully follow the instructions below. This will

ensure safe installation into a masonry, UL127-

listed manufactured fireplace or listed vent-free

firebox enclosure.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace cabinet (see Figure 4).

Note: When installing your gas logs into

a manufactured firebox, follow firebox

manufacturer’s instructions for minimum

clearances to combustible materials.

B. Clearances from the top of the fireplace open-

ing to the ceiling should not be less than 42".

NOTICE: Nonthermostat con-

trolled heaters may be used as a

vented product. If so, you must

always run heater with chimney

flue damper open. If running heater

with damper open, noncombus-

tible material above fireplace

opening is not needed. Go to In-

stalling Damper Clamp Accessory

for Vented Operation, page 11.

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

LOG SIZING REQUIREMENTS

Minimum Firebox Size Center

Log Size Height

Depth

Front

Width

Rear*

Width

18"

1"

14"

24"

20"

24"

1"

14"

28"

22"

*Measured at 14" depth