AIR FOR COMBUSTION

AND VENTILATION

Continued

Figure 3 - Ventilation Air from Outdoors

Outlet

Air

Ventilated

Attic

Outlet

Air

Inlet

Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

INSTALLATION

NOTICE: This heater is intended

for use as supplemental heat.

Use this heater along with your

primary heating system. Do not

install this heater as your pri-

mary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using heater. This will help

circulate the heat throughout the

house. In the event of a power

outage, you can use this heater

as your primary heat source.

WARNING: A qualified ser-

vice person must install heater.

Follow all local codes.

NOTICE: State or local codes

may only allow operation of this

appliance in a vented configura-

tion. Check your state or local

codes.

WARNING: Make sure the

selector switch is in the OFF po-

sition before installing heater.

WARNING: Before installing in

a solid fuel burning fireplace, the

chimney flue and firebox must be

cleaned of soot, creosote, ashes

and loose paint by a qualified chim-

ney cleaner. Creosote will ignite

if highly heated. A dirty chimney

flue may create and distribute soot

within the house. Inspect chimney

and firebox flue for damage. If

damaged, repair flue and firebox

before operating heater.

WARNING: Seal any fresh

air vents or ash clean-out doors

located on floor or wall of fire-

place. If not, drafting may cause

pilot outage or sooting. Use a

heat-resistant sealant. Do not

seal chimney flue damper.

WARNING: Never install the

heater

• in a bedroom or bathroom un-

less installed as a vented unit,

see page 11

• in a recreational vehicle

• where curtains, furniture, cloth-

ing or other flammable objects

are less than 42" from the front,

top or sides of the heater

• in high traffic areas

• in windy or drafty areas

ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or

ducts. You must provide two permanent openings:

one within 12" of the ceiling and one within 12"

of the floor. Connect these items directly to the

outdoors or spaces open to the outdoors. These

spaces include attics and crawl spaces. Follow the

National Fuel Gas Code, ANSI Z223.1/NFPA 54,

Section 5.3, Air for Combustion and Ventilation for

required size of ventilation grills or ducts.
IMPORTANT:

Do not provide openings for inlet

or outlet air into attic if attic has a thermostat-

controlled power vent. Heated air entering the attic

will activate the power vent.