Gas installation

This appliance should be fitted by a
C.O.R.G.I. registered fitter.
The installation must comply with Gas
Safety (installation and use) Regulations
1994.
It is illegal to provide any assistance in
the installation of gas appliance except
to C.O.R.G.I registered installers.

Any C.O.R.G.I registered fitter requiring
help must provide name, address and
registration number. Information supplied
will be validated before help is provided.

This appliance is predisposed and
adjusted to operate with Natural Gas at
20 mbar.

After connecting to the mains, check
that the couplings are correctly
sealed, using soapy solution, but
never a naked flame.

BURNERS

Auxiliary (A)

1,00

0,32

40

65*

Semi-rapid (SR)

1,60

0,39

43

85*

Rapid (R2)

2,40

0,58

55

110*

Rapid (R1)

3,05

0,67

60

115 (.15*)

Double-ring (DR)

3,20

0,77

62

125*

Nominal

input [kW]

Reduced

input [kW]

By-pass

[1/100 mm]

Ø injector

[1/100 mm]

Natural Gas - 20 mbar

*

= Injector brand

INJECTORS TABLE

GB

Cat:

I

2H

Gas Installation

If the gas tap becomes stiff, it is necessary to dismount it accurately clean it with
gasoline and spread a bit of special grease resistant to high temperatures on it.

The operations must be executed by a qualified technician.

Lubrication of the gas taps