Installation, Ventilation – Caple C761GSS User Manual

Page 5

Advertising
background image

5

The hob must be installed by a
qualified technician and in
compliance with local safety
standard.

Take care not to lose or mishandle
any parts when unpacking the
appliance.

Positioning the appliance

The hob must be installed a
minimum of 50 mm from the back
wall and 150 mm from any vertical
surface either side of the hob.

Adjacent units must be a
minimum of 450 mm above the
worksurface.

If you are installing a cooker hood
above the hob there must be a
minimum height of 750 mm
between the appliance.

If a cooker hood is not installed,
there must be a minimum height
of 900 mm between cabinets
above the hob.

This hob must not be installed
above refrigeration products.

450 mm

COOKER HOOD

750 mm

900 mm

cabinet only

(without cooker hood)

Fig. 2

Ventilation

All rooms require a window which can be opened or equivalent, while some rooms
require a permanent vent in addition to a window.

This unit must not be used in a room with less than 5 m

3

.

Room Volume

Air vent necessary (effective area)

5 m

3

100 cm

2

5 m

3

to 10 m

3

50 cm

2

Greater than 11 m

3

No air vent necessary

A room 5 m

3

to 10 m

3

with a door

No permanent air vent necessary

opening to the outside

The above requirements allow use of a gas oven and grill but if there are other fuel
burning appliances in the same room BS5440 part 2: 1989 (ventilation) should be
consulted to determine the necessary air venting requirements.

Installation