CB 2 Series

Administrator Guide

PROGRAMMING PRIMARY & SECONDARY MODES

1. Remove power from unit.
2. Short the Yellow wires together.
3. Restore power to the unit and wait until the unit begins to flash. Once the unit begins to flash,

remove the short. The unit will alternately demonstrate the Secondary-Flash Mode and Primary-

Steadyburn Mode that will be displayed during operation. For approximately 4 seconds the

Secondary-Flash Mode will be demonstrated, followed by the Primary-Steadyburn Mode.

4. To select the next mode of operation, momentarily short the yellow wires. The unit will cycle to

the next mode in the list above.

5. There are seven Flash Modes and three Steadyburn Modes combinations to choose from.
6. When you reach the desired mode of operation, remove power from the unit. You MUST leave

power disconnected for 20 seconds BEFORE reapplying. When power is reapplied, the unit will

operate as programmed above.

NOTE: If you do not leave power disconnected for 20 seconds before reapplying power, the light

will default to Program Mode.

MODE NUMBER

PRIMARY-STEADYBURN MODE

SECONDARY-FLASH MODE

1

High

Single - 60 FPM

2

OFF

Single - 60 FPM

3

Low

Single - 60 FPM

4

High

Single - 150 FPM

5

OFF

Single - 150 FPM

6

Low

Single - 150 FPM

7

High

Single - 375 FPM

8

OFF

Single - 375 FPM

9

Low

Single - 375 FPM

10

High

Neobe - 75

11

OFF

Neobe - 75

12

Low

Neobe - 75

13

High

Neobe - 150

14

OFF

Neobe - 150

15

Low

Neobe - 150

16

High

Double - 125

17

OFF

Double - 125

18

Low

Double - 125

19

High

Double - 250

20

OFF

Double - 250

21

Low

Double - 250

INPUT VOLTAGE RANGE: 12-24V AC or DC
TEMPERATURE RATING: -40

0

C to +65

0

C (-40

0

F to 149

0

F)

TYPICAL POWER CONSUMPTION AT 25

0

C

Voltage Flash Mode

Steady Mode - High

12V DC

0.24 A Max

0.24 A

24V DC

0.12 A Max

0.12 A

12V AC

1.1 A rms Max

0.53 A rms

24V AC

0.22 A rms Max

0.22 A rms

NOTE: Average current draw in Flash Mode will vary by selected Flash Mode. The above maximum amperage draw is

stated at Single 60 FPM.