CST-5005 C-Band Satellite Terminal
Remote Control Operation
Rev. 1
A–7
Clear
Program
Preset
Config
Command:
Response:
Status:
Response:
<add/CPGM_n'cr'
>add/CPGM_n'cr''lf']
<add/CPGM_'cr'
>add/CPGM_'cr'
Where: n = 1, 2, or 3.
1
xxxxxxxxxx'cr'
xxxxxxxxxx = 'Programmed' or 'None'.
2
xxxxxxxxxx'cr'
3
xxxxxxxxxx'cr''lf']
Allows the user to clear (unprogram) the frequency and
attentuator setting for one of three 'PreSet' selections.
RS-232
Address
Select
Command:
Response:
Status:
Response:
<add/AS_xxx'cr'
>add/AS_xxx'cr''lf']
<add/AS_'cr'
>add/AS_xxx'cr''lf']
Where:
add = current address.
xxx = new address, 1 to 255. Default address = 1.
RS-232
Baud Rate
Select
Command:
Response:
Status:
Response:
<add/BR_xxxxx'cr'
>add/BR_xxxxx'cr''lf']
<add/BR_'cr'
>add/BR_xxxxx'cr''lf']
Where: xxxxx = 300 to 19200, in standard settings of 300, 600,
1200, 2400, 4800, 9600, and 19200. Default = 9600.
RS-232
Parity
Select
Command:
Response:
Status:
Response:
<add/PS_xx'cr'
>add/PS_xx'cr''lf']
<add/PS_'cr'
>add/PS_xx'cr''lf']
Where: xx = OD (odd), EV (even, the default), or
NO (none - 8 bit).