Remote Control Operation

C5/K1/K3 Integrated Satellite Terminal System

B–6

Rev. 0

Set
Modulator
Output
Power Level

Command:
Response:

Status:

<add/MOP_snn.n'cr'
>add/MOP_snn'cr''lf']

>add/MOP_snn.n'cr''lf']

C-Band:

Where: snn.n = +25 to +38 in 1 steps.

K1 Ku-Band:

Where: snn.n = +17 to +30 in 1 steps.

K3 Ku-Band:

Where: snn.n = +22.0 to +35.0 in 0.1 steps (nominal
range in dBm).

Note: The MOP_ command will return status only when
local AUPC is enabled.

Scrambler
Enable

Command:
Response:

Status:
Response:

<add/SE_xxx'cr'
>add/SE_xxx'cr''lf']

<add/SE_'cr'
>add/SE_xxx'cr''lf']

Where: xxx = ON or OFF.

Differential
Encoder
Enable

Command:
Response:

Status:
Response:

<add/DENC_xxx'cr'
>add/DENC_xxx'cr''lf']

<add/DENC_'cr'
>add/DENC_xxx'cr''lf']

Where: xxx = ON or OFF.

Modulator
Type

Command:
Response:

Status:
Response:

<add/MT_xxxx'cr'
>add/MT_xxxx'cr''lf']

<add/MT_'cr'
>add/MT_xxxx'cr''lf']

Where: xxxx = EFD (EF DATA CLOSED NETWORK),
CSC (COMSTREAM CLOSED NETWORK), FDC
(FAIRCHILD CLOSED NETWORK).

Modulator
Encoder
Type

Command:
Response:

Status:
Response:

<add/MET_xxx'cr'
>add/MET_xxx'cr''lf']

<add/MET_'cr'
>add/MET_xxx'cr''lf']

Where: xxx = VIT (K-7 VITERBI ENCODER), SEQ
(SEQUENTIAL ENCODER).

Modulator
Spectrum
Rotation

Command:
Response:

Status:
Response:

<add/MSR_xxx'cr'
>add/MSR_xxx'cr''lf']

<add/MSR_'cr'
>add/MSR_xxx'cr''lf']

Where: xxx = NRM (normal spectrum), INV (inverted
spectrum).

Reed-
Solomon
Encoder
Enable

Command:
Response:

Status:
Response:

<add/RSEN_xxx'cr'
>add/RSEN_xxx'cr'lf']

<add/RSEN_'cr'
>add/RSEN_xxx'cr''lf']

Where: xxx = ON or OFF.

Transmit
BPSK Data
Ordering

Command:
Response:

Status:
Response:

<add/TDA_xxx'cr'
>add/TDA_xxx'cr''lf']

<add/TDA_'cr'
>add/TDA_xxx'cr''lf']

Where: xxx = NRM (STANDARD), INV (NON-
STANDARD).

Carrier Only
Mode

Command:
Response:

Status:
Response:

<add/COM_xxxxxx'cr'
>add/COM_xxxxxx'cr''lf']

<add/COM_'cr'
>add/COM_xxxxxx'cr''lf']

Where: xxxxxx = OFF (NORMAL-MODULATED), DUAL
(DUAL-CW), OFFSET (OFFSET-CW), CENTER
(CENTER-CW).

Advertising