MINIMAC Rack Management System
2–16
Rev. 0
2.4.3
COMM 5 Installation
The COMM 5 Rack is identified as the CST-5000 Rack (Figure 2-9). Install the
equipment as follows:
Note: The RFT-500 Redundancy System is an outside installation. Refer to the
Installation and Operation Manual for the proper procedures.
1.
Install the RFT-500 Redundancy System.
•
Set RFT A to Address 2.
•
Set RFT B to Address 3.
2.
Install an RSU-503L Switch. Set the switch as follows:
Command
Response
Set Baud Rate
9600 bit/s
Set Remote Address
1
Set Parity
EVEN
Set Remote Operation
RS-485 (2-wire)
3.
Attach a customer-fabricated cable to the REMOTE port (J16) of the RSU
Switch. Connect the 9-pin end to the MiniMAC port expander in the COMM 5
position.