Specifications, Wiring diagram – Desa B50H User Manual

Page 11

Advertising
background image

11

102553

(Pump Rotor, continued)

10.Install blades, pump plate, air filters,

and filter end cover.

11.Replace fan guard and upper shell.
12.Adjust pump pressure (see page 9).

Note:

If rotor is still binding, proceed as

follows.

13. Perform steps 1 through 6 (see page 10).
14. Place fine grade sandpaper (600 grit)

on flat surface. Sand rotor lightly in
“figure 8” motion four times (see Fig-
ure 14).

15.Reinstall insert and rotor.
16.Perform steps 10 through 12 above.

Sandpaper

Figure 14 - Sanding Rotor

.003"/.004" Gap
Measured With
Feeler Gauge

Blade

Rotor

Gap Adjusting Screw

Gap Adjusting Screw

Figure 13 - Gap Adjusting Screw Locations

SPECIFICATIONS

Output Rating (Btu/Hr.)

50,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity (U.S. Gal.)

4.0

Fuel Consumption (Gal. Per Hr.)

.40

Electric Requirements

120 V/60 Hz

Amperage (Normal Run)

2.0

Motor RPM

1725

Hot Air Output (CFM)

175

Pump Pressure (psi)

3.6

Shipping Weight (Approximate Pounds

35

Heater Weight without Fuel

(Approximate Pounds)

30

Figure 16 - Wiring Diagram

WIRING

DIAGRAM

Blue

Photocell

Power Plug

120V/60Hz

Ignitor

Ignitor

Blue

White

Red

Gray

Gray

Green

Motor

White

Black

AC Common (L2)

Photocell

Photocell Common

Motor Common

Motor

AC Hot (L1)

Ignitor Common

Ignition Control

Green

Advertising