102553

PRODUCT

IDENTIFICATION

Figure 2 - Cross Section Operational View

Fuel
Filter

Air Line
To Burner

Air
Output
Filter

Air Pump

Air Intake
Filter

Cool
Air
In

Fan

Combustion Chamber

Ignitor

Motor

Clean
Heated
Air Out

Ignition Control
Assembly

Figure 1 - 50,000 Btu/Hr Model

Handle

Fuel Cap

Lower Shell

Power Cord

Fuel Tank

Hot Air Outlet

Air Filter
End Cover

Fan Guard

Upper Shell

Air For Fuel
System

Air For Combustion
And Heating

Fuel

Side Cover

Ignition Control Assembly

(assembly on inside of

side cover)

Nozzle

THEORY OF

OPERATION

The Fuel System:

The air pump forces air through the air line. The air is then

pushed through the nozzle. This air causes fuel to lift from the tank. A fine mist of
fuel is sprayed into the combustion chamber.

The Air System:

The motor turns the fan. The fan pushes air into and around

the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System:

The ignition control assembly provides power to the

ignitor. This ignites the fuel/air mixture in the combustion chamber.

The Flame-Out Control System:

This system causes the heater to shut down

if the flame goes out.

1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If heater is damaged, promptly inform dealer

where you bought heater.

UNPACKING

Fuel