102553

Item

How Often

How To

Fuel tank

Flush every 150-200 hours

See Storing, Transporting, or

of operation or as needed.

Shipping, above.

Air output and

Replace every 500 hours of

See Air Output, Air Intake,

lint filters

operation or once a year.

and Lint Filters, page 8.

Air intake

Wash and dry with soap and

See Air Output, Air Intake,

filter

water every 500 hours of op-

and Lint Filters, page 8.

eration or replace as needed.

Fuel filter

Clean twice a heating season

See Fuel Filter, page 9.

or replace as needed.

Ignitor

No maintenance required.

Fan blades

Clean each season or as needed. See Fan, page 8.

Motor

Not required/permanently lubricated

PREVENTATIVE

MAINTENANCE

SCHEDULE

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

WARNING

STORING,

TRANSPORTING,

OR SHIPPING

Note:

If shipping, transport companies require fuel tanks to be empty.

1. Drain fuel tank. Drain fuel through fuel cap opening. Be sure all fuel is re-

moved.

2. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank,

stir, and drain again. This will prevent excess debris from clogging filters
during future use.

3. Replace fuel cap. Properly dispose of old and dirty fuel. Check with local

automotive service stations that recycle oil.

4. If storing, store heater in dry place. Make sure storage place is free of dust and

corrosive fumes.

IMPORTANT:

Do not store kerosene over summer months for use during next

heating season. Using old fuel could damage heater.