8

102553

SERVICE

PROCEDURES

WARNING

Upper Shell Removal

1. Remove screws along each side of

heater using 5/16" nut-driver. These
screws attach upper and lower
shells together.

2. Lift upper shell off.
3. Remove fan guard.

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

!

Fan

Motor

Fan

IMPORTANT:

Remove fan from

motor shaft before removing motor
from heater. The weight of the motor
resting on the fan could damage the
fan pitch.

1. Remove upper shell (see above).
2. Use 1/8" allen wrench to loosen

set-screw which holds fan to motor
shaft.

3. Slip fan off motor shaft.
4. Clean fan using soft cloth mois-

tened with kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place

fan hub flush with end of motor
shaft (see Figure 4).

7. Place setscrew on flat of shaft.

Tighten setscrew firmly (40-50
inch-pounds).

8. Replace fan guard and upper shell.

Air Output, Air Intake, and
Lint Filters

1. Remove upper shell (see above).
2. Remove filter end cover screws

using 5/16" nut-driver.

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter

(see Preventative Maintenance
Schedule,
page 6).

6. Replace filter end cover.
7. Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

Figure 3 - Upper Shell Removal

Figure 5 - Air Output, Air Intake, and Lint Filters

Flush

Setscrew

Motor
Shaft

Figure 4 - Fan Cross Section

Air Intake Filter

Filter End Cover

Fan Guard

Air Output
Filter

Lint Filter

Upper
Shell

Fan
Guard