Reading position, Input/output connections – Datalogic Scanning DS1100 User Manual

Page 4

Advertising
background image

DS1100 QUICK GUIDE

4

Reading Position:


In DS1100-XXX1 models the laser beam is emitted from the output window with a 12° (± 2) skew angle.

± 2°

Laser

Beam

DS1100-XXX1

90° Reading Window

Position

DS1100-XXX0

Direct Reading

Window Position

Laser

Beam

12° ± 2

Input/Output Connections:

Input Input

13/9

19

VS 5 Vdc

EXT TRIG -

12/22 GND

EXTERNAL TRIGGER

Ground

V

DS1100

Signal

+ 5 V

47 K

NPN Ext. Trigger Input Command (5 Vdc Photocell)

18

IN1 -

12/22

GND

Ground

DS1100

+ 5 V

47 K

User Interface

IN1 Input Command

Input Output

13/9

19

VS 5 Vdc

EXT TRIG -

12/22 GND

EXTERNAL TRIGGER

Ground

V

DS1100

Signal

+ 5 V

47 K

V

max

30 Vdc max

NPN Ext. Trigger Input Command (Photocell max 30 Vdc)

USER INTERFACE

Vext 50 Vdc max., 50 mA max

.

DS1100

8/11

12/22

OUT1+ / OUT 2+

GND

Ground

Output Open Collector Connections



V

CE

max = 50 Vdc

I max = 50 mA continuous