Over-capacity limit, Over range, Under range – Digi-Star EZ400 User Manual

Page 16: Low battery indication

Advertising
background image

Weighing Errors

12

EZ400 User’s Manual

D3655-US Rev E

WEIGHING ERRORS

Over-Capacity Limit (

OVRCAP

)

The display shows the message "OVRCAP" if the weight on the scale system

exceeds the capacity limit. The capacity value is entered in SETUP to warn of

overloading the scale system.

Over Range (

+RANGE

)

The display shows the message "

+RANGE

" if the weight on the scale system

exceeds the maximum weight measurable by the scale system. The over

range value is always the system’s maximum A/D counts multiplied by the

scaling factor. The actual weight at which over range occurs depends on the

calibration, zero, and display count size.

Under Range (

-RANGE

)

The display shows the message "

-RANGE

" if the weight on the scale system is

less than the minimum weight measurable by the scale system. The under

range value is always the system’s minimum A/D counts multiplied by the

scaling factor. The actual weight at which under range occurs will depend on

the; calibration, zero, and display count size.

Low Battery Indication (

LO BAT

)

If the supply voltage drops below the (10.5 Volts), the message

RECHARGE

BATTERY - TURNING OFF

and

LO BAT

will periodically show on the display to alert

the operator of the low battery condition.

RUN SELF TEST

1. Press then during

normal system operation to start

self-test.

1

Advertising