Installation – Desa VYM27NR User Manual

Page 15

Advertising
background image

www.desatech.com

108382-01G

15

INSTALLATION

Continued

Figure 18 - Installing Bottom Log (#1)

Bottom Log (#1)

Burner

Chassis

Grate

Burner Port

Figure 19 - Installing Log set (Top View)

Logs

Burner Ports

Figure 20 - Installing Top Log (#2)

Top Log

(#2)

Peg

3. Position log piece (#3) by aligning holes on

underside with remaining pegs on bottom log

(see Figure 21, page 16).

4. Place lava rock around base of heater.

pRESSURE TESTING HEATER GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 15,

page 14).

2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Make sure control knob of heater is in the OFF

position.

4. Check all joints from equipment shutoff valve

to control valve (see Figure 16 or 17, page 14).

Apply a noncorrosive leak detection fluid to gas

joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Light heater (see Operating Heater, pages 16).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Appli-

ance, page 17).

INSTALLING LOGS

WARNING: Failure to position

the parts in accordance with these

diagrams or failure to use only

parts specifically approved with

this heater may result in property

damage or personal injury.

CAUTION: After installa-

tion and periodically thereafter,

check to ensure that no flame

comes in contact with any log.

With the heater set to High, check

to see if flames contact any log. If

so, reposition logs according to

the log installation instructions

in this manual. Flames contact-

ing logs will create soot.

It is very important to install the logs exactly as

instructed. Do not modify logs. Only use logs

supplied with heater.

1. Place bottom log (#1) on grate to fit as illustrated

in Figure 18. Make sure open areas of log set line

up with burner ports (see Figure 19). Log will fit

securely on chassis. IMPORTANT: Make sure

log does not cover any burner ports.

2. Facing front of unit, place top log (#2) onto

the pegs in the center of the bottom log (see

Figure 20).

Advertising