Operating heater, Installation – Desa VYM27NR User Manual

Page 16

Advertising
background image

www.desatech.com

108382-01G

16

INSTALLATION

Continued

Figure 21 - Installing Log Piece (#3)

Log Piece (#3)

Peg

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, don’t

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified

service technician to inspect the appliance and

to replace any part of the control system and

any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING:

• If fireplace has glass doors,

never operate this heater with

glass doors closed. If you op-

erate heater with doors closed,

heat buildup inside fireplace

will cause glass to burst. Make

sure there are no obstructions

across openings of fireplace.

• You must operate this heater

with a fireplace screen in place.

Make sure fireplace screen is

closed before running heater.

NOTICE: During initial operation of

new heater, burning logs will give

off a paper-burning smell. Open

damper or window to vent smell.

This will only last a few hours.

Note:

Homeowners generally prefer to operate

their heater with the chimney damper closed.

This will put all the heat into the room. How-

ever, there may be times you will desire the full

flames of the HI heat setting but will find the

heat output excessive. You can open the chim-

ney damper (if you have one) fully or partially

to release some of the heat.

WARNING: Damper handle

will be hot if heater has been

running.

1. STOP! Read the safety information, col-

umn 1.

2. Make sure equipment shutoff valve is

fully open.

3. Set switch in OFF position.

WARNING: Burner will come

on automatically within one

minute when the selector switch

is in the ON position after the

pilot is lit.

4. Press in and turn control knob clockwise

to the OFF position.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

Advertising