TROUbLESHOOTING

Continued

OBSERVED PROBLEM

Moisture/condensation noticed

on windows

Heater produces a whistling noise

when burner is lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Remote does not function

Heater produces a clicking/tick-

ing noise just after burner is lit

or shut off

Heater produces unwanted

odors

Heater shuts off in use (ODS

operates)

Gas odor even when control knob

is in OFF position

POSSIBLE CAUSE

1. Not enough combustion/ven-

tilation air

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Battery is not installed. Battery

power is low

1. Metal expanding while heating

or contracting while cooling

1. Heater burning vapors from

paint, hair spray, glues, clean-

ers, chemicals, new carpet, etc.

(See IMPORTANT statement

above)

2. Gas leak. See Warning state-

ment at top of page 25

1. Not enough fresh air is avail-

able

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak. See Warning state-

ment at top of page 25

2. Control valve defective

REMEDY

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum installa-

tion clearances (see pages 8

through 11)

4. Clean burner (see Cleaning

and Maintenance, page 20) or

replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet

cleaners, or similar products

1. Replace 9-volt batteries in re-

ceiver and hand-held remote

1. This is common with most heat-

ers. If noise is excessive, contact

qualified service person

1. Open window and ventilate

room. Stop using odor caus-

ing products while heater is

running

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 14)

1. Open window and/or door for

ventilation

2. Contact local natural or pro-

pane/LP gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 20)

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 14)

2. Replace control valve

Advertising