Installation, Built-in fireplace installation, Continued – Desa CF26PTA User Manual

Page 9

Advertising
background image

www.desatech.com

113896-01A

9

BUILT-IN FIREPLACE
INSTALLATION

Built-in installation of this fireplace involves in-

stalling fireplace into a framed-in enclosure. This

makes the front of fireplace flush with wall. Follow

the instructions below to install the fireplace in this

manner. If installing a built-in mantel above the

fireplace, you must follow the clearances shown

in Figure 9, page 11. If using for built-in instal-

lation off of the floor, follow clearances shown

in Figure 4.

Actual

Framing

Height

26"

26

7

/

8

"

Front Width

26

3

/

4

"

26

7

/

8

"

Depth

9

1

/

2

"

10

1

/

2

"

Bottom

3/4"

3/4"

1. Frame in rough opening. Use dimensions shown

in Figure 6 for the rough opening.

If installing in a corner, use dimensions shown

in Figure 7 for the rough opening. The height

is 26

1

/

8

" which is the same as the wall opening

above.

2. An optional blower accessory is available (see

Accessories, page 32). There are two options

for connecting blower to electrical source.

Option one:

Have a licensed electrician install

a properly grounded, three-prong 120-volt

electrical outlet at fireplace location. Locate

outlet inside the framed enclosure. Blower

power cord will plug into this outlet.

INSTALLATION

Continued

An optional blower kit is available from your

dealer. See Accessories, page 32. If planning to use

blower, locate fireplace near an electrical outlet.
Note:

When installing fireplace directly on carpet-

ing, tile or other combustible material, other than

wood flooring, the fireplace shall be installed on a

metal or wood panel extending the full width and

depth of the fireplace.

36

5

/

8

"

25

7

/

8

"

51

3

/

4

"

26

7

/

8

"

Figure 7 - Rough Opening for Installing

in Corner

26

7

/

8

"

26

7

/

8

"

3/4" Off
The Floor
Minimum

10

1

/

2

"

Figure 6 - Rough Opening for Installing

in Wall

Figure 5 - Mounting Clearances As

Viewed From Front of Fireplace Shown

with Optional Mantel

Figure 4 - Mounting Clearances As

Viewed From Front of Fireplace Shown

Built In The Wall

6"

Minimum

From

Sides Of

Fireplace

Left

Side

CEILING

42" Minimum

FLOOR

Right

Side

Top Of

Mantel Can

Be Flush

With Wall

Left

Side

CEILING

Right

Side

42"

Minimum

0" Minimum Clearance To Top Surface Of
Carpeting, Tile Or Other Combustible Material

0" Minimum Clearance To Top Surface Of
Carpeting, Tile Or Other Combustible Material