  FAC (FiberPlex Auxiliary Control) – Dual RJ11 connections provide an RS422 connection for accessing reporting and control information 

from the WDM16/8. This is a daisy chained buss allowing the connection of multiple units with one control computer. The use of this 
port is described in more detail later in this manual. 

 

11

12

13

 

Figure 4 PSMAC Power Supply Module 

  AC Inlet – Power is provided through a Neutrik™ powerCON TRUE1 connector. Connect to 100‐240 VAC power source using the supplied 

AC power cord. 

  Fuse Compartment – Contains the fuse for the power supply. The fuse compartment cap can be twisted off using a flat head 

screwdriver and the fuse removed. Replace fuse with a 2A time‐delay fuse (Littlefuse model 218.002 Slo‐Blo). Additional information is 
later in this manual. 

  Status Indicator – Has the same function as PS1 

 and PS2 

 on the front panel as described earlier in this section. 

 