Flowserve WPG IDP User Manual

Page 7

Advertising
background image

WPG and WPH USER INSTRUCTIONS ENGLISH 26999969 10-12

Page 7 of 40

flowserve.com

1.6.4.2 Marking
An example of ATEX equipment marking is shown
below. The actual classification of the pump will be
engraved on the nameplate.

II 2 GD c IIC 135 ºC (T4)

Equipment Group
I = Mining
II = Non-mining

Category
2 or M2 = high level protection
3 = normal level of protection

Gas and/or dust
G = Gas, D = Dust

c = Constructional safety

(in accordance with EN13463-5)

Gas Group
IIA – Propane (typical)
IIB – Ethylene (typical)
IIC – Hydrogen (typical)

Maximum surface temperature (Temperature Class)
(see section 1.6.4.3.)

1.6.4.3 Avoiding excessive surface temperatures

ENSURE THE EQUIPMENT TEMPERATURE

CLASS IS SUITABLE FOR THE HAZARD ZONE

Pumps have a temperature class as stated in the
ATEX Ex rating on the nameplate. These are based
on a maximum ambient of 40

ºC (104 ºF); refer to

Flowserve for higher ambient temperatures.

The surface temperature on the pump is influenced
by the temperature of the liquid handled. The
maximum permissible liquid temperature depends on
the ATEX temperature class and must not exceed the
values in the table that follows:

Maximum permitted liquid temperature for pumps

Temperature class

to EN13463-1

Maximum surface

temperature permitted

Temperature limit of

liquid handled *

T6
T5
T4
T3
T2
T1

85

°C (185 °F)

100

°C (212 °F)

135

°C (275 °F)

200

°C (392 °F)

300

°C (572 °F)

450

°C (842 °F)

Consult Flowserve
Consult Flowserve

115

°C (239 °F) *

180

°C (356 °F) *

275

°C (527 °F) *

400

°C (752 °F) *

* The table only takes the ATEX temperature class into consideration.

Pump design or material, as well as component design or material,
may further limit the maximum working temperature of the liquid.


The temperature rise at the seals and bearings and
due to the minimum permitted flow rate is taken into
account in the temperatures stated.

The operator is responsible to ensure that the
specified maximum liquid temperature is not
exceeded.

Temperature classification

“Tx” is used when the liquid

temperature varies and when the pump is required to be
used in differently classified potentially explosive
atmospheres. In this case the user is responsible for
ensuring that the pump surface temperature does not
exceed that permitted in its actual installed location.

If an explosive atmosphere exists during the
installation, do not attempt to check the direction of
rotation by starting the pump unfilled. Even a short
run time may give a high temperature resulting from
contact between rotating and stationary components.

Avoid mechanical, hydraulic or electrical overload by
using motor overload trips, temperature monitors or a
power monitor and make routine vibration monitoring
checks.

In dirty or dusty environments, make regular checks
and remove dirt from areas around close clearances,
bearing housings and motors.

Where there is any risk of the pump being run against a
closed valve generating high liquid and casing external
surface temperatures fit an external surface
temperature protection device.

1.6.4.4 Preventing the build up of explosive
mixtures

ENSURE THE PUMP IS PROPERLY FILLED

AND VENTED AND DOES NOT RUN DRY

Ensure the pump and relevant suction and discharge
pipeline system is totally filled with liquid at all times
during the pump operation, so that an explosive
atmosphere is prevented.

In addition it is essential to make sure that seal
chambers, auxiliary shaft seal systems and any
heating and cooling systems are properly filled.

If the operation of the system cannot avoid this
condition, fit an appropriate dry run protection device
(for example liquid detection or a power monitor).

To avoid potential hazards from fugitive emissions of
vapour or gas to atmosphere the surrounding area
must be well ventilated.

Advertising
This manual is related to the following products: