2.2.2 Pump masses

All masses are in kg:




MASS OF BARE SHAFT PUMPS ACCORDING TO STAGE NUMBER

PUMP TYPES

2

3

4

5

6

7

8

9

10

11

12

32 NM

45

50

55

60

65

70

75

80

85

90

95

40 NM

56

65

74

83

92

101

110

119

128

50 NM

82

92

102

112

122

132

142

152

65 NM

111

123

135

147

159

171

183

80 NM

146

165

184

203

222

241

100 NM

245

285

325

365

405

445

485

525

125 NM

466

509

552

595

638

681

724

767

810

150 NM

646

756

864

973

1082

1191

1300

1409

1518

1627

1736

200 NM

1048

1190

1332

1474

1616

1758

1900

2042

2184

2326

201 NM

1300

1500

1700

1900

2100

102 NM

250

289

328

367

406

445

484

523

562

122 NM

575

650

725

800

875

152 NM

820

940

1060

1180

1300

202 NM

1000

1200

1400

1600

252 NM

1800

2120

2440

2760

352 NM

3900

4475

5050

All motors (for masses see the motor

description plate) must be handled with a winch.

For masses above 25 kg (55 lb), manual

handling is forbidden.


2.3 Lifting

2.3.1 Slinging of motor pumps units

Use handling means in accordance with

motor pump unit mass mentioned on the CE plate.
For the masses of the pumps bare end of shaft
see table § 2.2.2 and nameplate.

To avoid distortion, the pump unit

should be lifted as shown.

A crane must be used for all pump sets in

excess of 25kg (55 Ib). Fully trained personnel
must carry out lifting, in accordance with local
regulations.

Motor pump unit

Bareshaft pump

When handling always wear gloves, safety

boots and an industrial safety helmet.

For masses above 25 kg (55 lb), manual

handling is forbidden.