6.2.1 Standard maintenance

Roller bearing

6.2.1.1 Grease lubricated bearings

The bearings fitted are prepacked with grease at the
factory. When the regreasing period is reached it is
necessary to remove as much of the old grease as
possible with a clean lint free cloth and repack the
bearings with fresh grease.

Lubrication frequencies in

hours of operation*

Quantity (cm

3

)

Pump

type

1450
min

-1

1750
min

-1

2900
min

-1

3500
min

-1

Opposite

side

Coupling

side

32 NM

3000 2200 1500 1200

8

8

40 NM

3000 2200 1500 1200

8

8

50 NM

3000 2200 1500 1200

16

8

65 NM

2700 2000 1400 1100

16

8

80 NM

2500 1700 1300 1000

20

10

100 NM

8000 6500 5500 5000

36

18

125 NM

6000 5000 2500 2000

20

10

150 NM 2

to 4

stages

7500 6000

26

26

150 NM 5

to 12

stages

7500 6000

52

26

200 NM 2

to 3

stages

6500 5000

33

33

200 NM 4

to 11

stages

6500 5000

66

33

201 NM

4000 3000

35

17

102 NM

8000 7000

40

20

122 NM

7000 6000

30

15

152 NM

6000 5000

40

20

202 NM

5500 4500

60

30

252 NM

5000 4000

60

30

352 NM

4000

90

45

* At least once a year.

The grease used in factory for first filling is:

SHELL ALVANIA R2

Its equivalents: MOBIL : Mobilux EP 2,

TOTAL : Multis 2,

ELF : ELF MULTI