Flowserve NM User Manual

Page 26

Advertising
background image

NM USER INSTRUCTIONS ENGLISH 71576289 - 11/09

Page 26 of 48

6.2.1.2 Oil lubricated bearings
Normal oil change intervals are 2 000 to 3 000
operating hours or at least every 6 months. For
pumps on hot service or in severely damp or
corrosive atmosphere, the oil will require changing
more frequently.

Lubricant and bearing temperature analysis can be
useful in optimizing lubricant change intervals.

The lubricating oil should be a high quality mineral oil
having foam inhibitors. Synthetic oils may also be
used if checks show that the rubber oil seals will not
be adversely affected.

The bearing temperature may be allowed to rise to
50 ºC (122 ºF).above ambient, but should not exceed
82 ºC (180 ºF). A continuously rising temperature, or
an abrupt rise, indicate a fault.

Oil

Splash lubrication

Viscosity

cSt 40 ºC

32

68

46

Temp. maximum

ºC (ºF)

-5 to 65 (-23 to 149)

-5 to 80 (-23 to 176)

-

C

e

n

ti

fu

g

a

l

p

u

m

p

lu

b

ri

c

a

ti

o

n

Designation

according to

DIN51502 ISO VG

HL/HLP 32

HL/HLP 68

HL/HLP 46

BP

BP Energol HL32

BP Energol HLP32

BP Energol HL68

BP Energol HLP68

BP Energol HL46

BP Energol HLP46

DEA

Anstron HL32

Anstron HLP32

Anstron HL68

Anstron HLP68

Anstron HL46

Anstron HLP46

Elf

OLNA 32

HYDRELEF 32

TURBELF 32

ELFOLNA DS32

TURBELF SA68

ELFOLNA DS68

TURBELF SA46

ELFOLNA DS46

Esso

TERESSO 32

NUTO H32

TERESSO 68

NUTO H68

TERESSO 46

NUTO H46

Mobil

Mobil DTE oil light

Mobil DTE13M

Mobil DTE24

Mobil DTE oil heavy medium

Mobil DTE26

Mobil DTE oil medium

Mobil DTE15M

Mobil DTE25

Q8

Q8 Verdi 32

Q8 Haydn 32

Q8 Verdi 68

Q8 Haydn 68

Q8 Verdi 46

Q8 Haydn 46

Shell

Shell Tellus 32
Shell Tellus 37

Shell Tellus 01 C 68

Shell Tellus 01 68

Shell Tellus 01 C 46

Shell Tellus 01 46

Texaco

Rando Oil HD 32

Rando Oil HD-AZ-32

Rando Oil 68

Rando Oil HD C-68

Rando Oil 46

Rando Oil HD B-46

O

il

c

o

m

p

a

n

ie

s

a

n

d

l

u

b

ri

c

a

n

ts

Wintershall

(BASF Group)

Wiolan HN32
Wiolan HS32

Wiolan HN68
Wiolan HS68

Wiolan HN46
Wiolan HS46

Oil volume (in liter)

Pump type

Drive end

bearingt

Non-drive end

bearing

202 NM

3.8

3.8

252 NM

3.8

3.8

6.2.2 Routine inspection (daily/weekly)

The following checks should be made

and the appropriate action taken to remedy any
deviations:
a) Check operating behavior. Ensure noise,

vibration and bearing temperatures are normal.

b) Check that there are no abnormal fluid or

lubricant leaks (static and dynamic seals) and
that any sealant systems (if fitted) are full and
operating normally.


c) Pump fitted with a stuffing box: leakage of 20

drops per minute.

d) Pump fitted with a mechanical seal: no leakage.
e) Check the level and condition of oil lubricant. On

grease lubricated pumps, check running hours
since last recharge of grease or complete
grease change.

6.2.3 Periodic inspection (six monthly)

a)

Check foundation bolts for

security of attachment and corrosion.

b) Check pump-running records for hourly usage to

determine if bearing lubricant requires changing.

c) The coupling should be checked for correct

alignment and worn driving elements.

Advertising