Flowserve ISC2 Dual metal bellows sea User Manual
Page 11
11
Figure 27
Figure 28
Figure 29
holding the collar in compression, tighten the
quarter-dog set screws [57.1] into the holes in
the sleeve until snug. If the seal does not contain
quarter-dog set screws then tighten the set
screws [57] into the sleeve [1]. See Figure 27.
Caution:
Over tightening will cause
distortion of the sleeve assembly [1]. Check
integrity of the sleeve with a plug of the
appropriate size to ensure no distortion has
occurred.
6.22 Install the sleeve O-ring [19] into the ID groove of
the sleeve assembly. See Figure 28.
6.23 The cartridge seal assembly is now ready for
testing.
6.24 Adhere the gland gasket [18] to the inner gland
gasket surface with a spray adhesive such as 3M
Super 77
®
. See Figure 29.
6.25 Permanently mark the seal type ISC2-BB, seal
size and gland ring material clearly on the gland
surface. See Figure 1 for placement location.
ISC2-BB
M060
C-276
Example
inch
marking
ISC2-BB
1.875
316 SS
Example
metric
marking