Flowserve MSS Series User Manual

Page 3

Advertising
background image

3

Notice:

Cleanliness during installation is crucial to the satisfactory

operation of the MSS seal.

Caution:

Installation of this seal requires the use of an adhesive to bond

the O-ring secondary seals together. Do not allow the

adhesive to come in contact with skin.

There are two basic models of the MSS seal, Piloted

, see Figure 2,

page 4, and Non-Piloted, see Figure 3, page 8.

Seal Chamber Requirements

Figure 1

Face of seal housing to be square to the

axis of the shaft to within 0.5 mm (.020 inch)

FIM and have a 1.6 mm (63√ m inch) R

a

finish or better

A

J

B

Sleeve or

shaft finish

to be 0.8 mm

(32√ m inch)

R

a

or better

Shaft or Sleeve

OD ±.02 mm

(±.001 inch)

• Bearings must be in good condition

• Maximum axial movement of shaft (end play) = 0.25 mm (0.010inch) FIM

• Maximum combined shaft eccentricity and shaft deflection at face of housing

total = 3.8 mm (0.150 inch) FIM