3.1 Spray one end of the split gland gasket O-ring 18 with the

adhesive accelerator provided. Apply one drop of the adhesive

provided to the other end. Position the split O-ring around the shaft

carefully aligning the two ends and bond the joint ends together.

Hold

for one minute to assure a suitable bond. Lubricate the O-ring

with the silicone lubricant provided. Place the bonded O-ring on the

seal chamber (stuffing box) face.

3.2 Remove the retainer halves 142 from the face of the gland halves

and save the retainer halves and cap screws 40.3 for Step 3.8.

3.3 Position the gland ring halves (1) around the shaft and fasten

them loosely together using the shoulder screws 414.1 provided.

3.4 Use some silicone lubricant provided to hold the gland gasket

O-ring 18 in its groove and position the gland on the seal chamber

face by loosely tightening the nuts or bolts.

3.5 Bond one of the split stationary face seat gasket O-rings 13

and lubricate as in Step 3.1. Place the bonded O-ring in the gland

counter-bore.

3.6 Install the stationary face halves 14 around the shaft with the

lapped face outward (non-lapped face is identified with a groove

or part marking) away from the seal chamber face. Insert the

stationary face into the gland bore and nest it in the O-ring 13 while

making sure there is no sealing face mismatch at joints. If mismatch

is present, gently remove it.

Important: Be sure the stationary face joints are in line with the
gland ring joints.

3.7 Bond and lubricate the second stationary face mounting O-ring

13 around the shaft as in Step 3.1 and place it over the stationary

face outer shoulder.

3.8 Securely attach the retainer halves 142 to the face of the gland

using cap screws 40.3 while positioning the retainer over the outer

stationary face mounting O-ring.

3.9 Tighten the shoulder screws 414.1 in the gland ring halves while

feeling for sealing face mismatch at the stationary face joints. If any

mismatch occurs, loosen the shoulder screws 414.1 and shift the

stationary face halves to remove the mismatch then continue with

tightening the shoulder screws.