2.4 Position the gland ring halves 11 around the shaft with the

counter-bore facing the stationary face. Place the gland halves

around the stationary face and fasten them together using the

shoulder screws 414.1 provided. Be sure the gland ring joints are in

line with the stationary face joints

and the two bolt holes are in

line with the bolt holes or studs in the seal chamber face.

While

tightening the shoulder screws, feel for sealing face mismatch at the

stationary face joints. If any mismatch occurs loosen shoulder screws

414.1 and shift the stationary face halves until no mismatch is felt and

continue with tightening shoulder screws.

Note

: Do not attempt to remove sealing face mismatch with the gland

joint shoulder screws 414.1 fully tightened. Doing so may

damage the stationary face.

2.5 Carefully fasten the gland to

the seal chamber

by tightening

the gland fasteners to a 3.4

N-m (30 lb-in) maximum torque

while feeling for sealing face

mismatch at the stationary face

joints. If any mismatch occurs,

loosen the gland fasteners and

shoulder screws 414.1 and repeat

steps in 2.4 to remove sealing

face mismatch. Then proceed with

tightening gland fasteners while

again checking for sealing face mismatch.

Important: Do not overtighten the gland nuts or bolts

as over-tightening

on some equipment may cause the stationary face to distort which may

result in leakage at the sealing face. It is not necessary for the gland to

have metal-to-metal contact with the seal chamber face for the inner

stationary face O-ring to form a seal. The stationary face must,

however, be square with the axis of the shaft to within 0.020 inch FIM.

2.6 Mount the rotating seal face halves 15 around the shaft and fasten

them together using the cap screws 40 provided, tighten to a 3.4 N-m

(30 lb-in) torque maximum. Check for seal face joint mismatch. If any

mismatch exists, loosen the cap screws and shift the rotating seal face

halves until no mismatch is felt. Retighten the cap screws.

Note: There are threads on both halves of the rotating seal face.

Align halves carefully so as to not allow a gap between halves

during tightening.

6

Fasten the gland ring to the
seal housing

Step 2.5