12. Slide fitting nuts into place and finger tighten.

13. Remove the fitting nuts and ferrules from the fittings

on the right side of the heat exchanger and the filter.

Slide them onto the “L” shaped tubing.

14. Insert the “L” shaped tube into the right side of the heat

exchanger and the filter. Verify tubing ends are the

correct length. Cut to fit if required. Proceed to the next

step once the tubing is the correct length.

15. Slide tube fitting nut and ferrule onto each end of the

tubing.

16. Insert tubing into the fittings on the heat exchanger

and filter.

17. Slide fitting nuts into place and finger tighten.

18. Square the mounting brackets with the manifold block.

See Figure 4. Tighten the mounting bolts and the U-

bolt nuts. Do not over tighten.

19. Hold tubing into position and tighten each nut with a

wrench until tight. Do not over tighten.

20. Disconnect the existing cooling media lines from the

reservoir’s internal heat exchanger.

21. Apply Teflon tape and/or Jomar pipe dope or equal to

the 1/2” NPT plug threads. Start no closer to the end

of the threads than the 2nd thread.

22. Thread the plugs into the reservoir’s internal heat

exchanger and tighten. Do not over tighten.

23. Installation is complete.

24. It is the responsibility of the customer to connect to the

heat exchanger cooling media ports.

Note: For additional cooling capacity run cooling media

through both the internal and external cooling coils

in series.

10

mounting

bracket

4.50"

tubing and

fittings

heat

exchanger

cooling port

orientation

mounting

bracket

Figure 4

Figure 5