3 Single Seal Piping and OperationalRecommendation

3.1 Install an adequate seal flush system. The ISC requires a clean

cool environment for maximum seal life. With a clean cool product,

use a bypass flush from the pump discharge (piping plan 11*) or a

bypass flush to the pump suction (piping plan 13). With clean hot

products use a bypass flush through a cooler (piping plan 21). With

abrasive products or products that are incompatible with the seal,

use a flush from a clean external source (piping plan 32).

a

b

Shaft rotation from exposed end of gland

Figure 7

*Note: All piping plan designations used in these instructions are from API 682.

for the corresponding ASME B73 piping plan designation, please add a

"73" in front of the referenced piping plan.

For Piping Plans 11, 21 and 32:

Shaft Rotation

Inlet

Plugged

(from exposed end of gland)

Port

Clockwise (CW)

Port b Port a

Counterclockwise (CCW)

Port a Port b

For Piping Plan 13:

Shaft Rotation

Outlet

Plugged

(from exposed end of gland)

Port

Clockwise (CW)

Port a Port b

Counterclockwise (CCW)

Port b Port a