Double isc with supply tank figure 9 – Flowserve ISC Series User Manual

Page 12

Advertising
background image

12

4.2 For dual pressurized seal (double seal) operation, supply a clean

compatible barrier fluid to the inlet port at a pressure at least

170 kPa (25 psi) above the seal chamber pressure. See Figure 9.

The pressure of the barrier fluid must not exceed the recommended

maximum pressure. Flowserve can supply information on barrier

fluid flow requirements based on seal size, product temperature,

barrier fluid characteristics, and shaft speed.

4.3 For dual unpressurized (tandem seal) operation, supply a clean

compatible buffer fluid to the inlet port at a pressure below the seal

chamber pressure. See Figure 10. The pressure in the seal

chamber must not exceed the recommended maximum pressure.

Flowserve can supply information on buffer fluid flow requirements

based on seal size, product temperature, buffer fluid characteristics,

and shaft speed.

Double ISC with Supply Tank

Figure 9

Bypass

Flush to

Gland

Flush Port

Supply Tank

Assembly with

Cooling Coils

1.2 m (4 feet)

maximum

Pressure

Source

0.45 - 0.6 m

(1.5 - 2 feet)

minimum

Orifice
Option

Advertising